大腿假肢支撐期有限元分析

Finite element analysis of trans-femoral prosthesis with liner in stance phase

作者: 李亞楠  錢秀清  孫翠蓮  劉志成 
單位:<span style="font-family:宋體">首都醫(yī)科大學(xué)生物醫(yī)學(xué)工程學(xué)院</span><span style="font-family:宋體">(北京</span>100069<span style="font-family:宋體">)</span><p><span style="font-family:宋體">首都醫(yī)科大學(xué)臨床生物力學(xué)應(yīng)用基礎(chǔ)研究北京市重點實驗室</span><span style="font-family:宋體">(北京</span> 100069<span style="font-family:宋體">)</span></p>
關(guān)鍵詞: 大腿假肢;  應(yīng)力分布;  硅膠套;  步態(tài);  有限元分析 
分類號:R318.04
出版年·卷·期(頁碼):2018·37·2(116-121)
摘要:

Objective To analyze the influence of material properties of liners on pressure distribution between residual limb and socket during the stance phase, which provides reference for the fitting scheme of liners for trans-femoral prosthesis. Methods CT images of stump and socket were obtained with computer tomography technology, and 3D models were obtained with information science and engineering methods, such as socket, liner, amputation, bones. Then we adjusted the models according to the changes of hip joint in stance phase, obtained the assemble model of phases of initial contact, loading response, mid-stance, terminal stance, pre-swing. We analyzed the assemble models with nonlinear finite element methods according to the measured results of ground reaction force and the changesof hip joint through Motion and Kistler. On this basis, we simulated the influence of material properties of the liners on the equivalent stress and the maximum shear stress distribution between stump and socket. Results With different liner elastic modulus, the maximum equivalent stress and shear stress of stump appeared in the medial residual limb and in the position of the residual limb corresponding to the edge of socket in phases of initial contact, loading response, mid-stance, and terminal stance. The maximum equivalent stress and shear stress of stump appeared in the medial residual limb, in the position of the residual limb corresponding to the edge of socket and around the ischium in phase of pre-swing. When the elastic modulus of the silicone liner changed at the range of 0. 98 MPa to 2.70 MPa, the equivalent stress was in the range of 13. 85 k Pa to 23. 55 k Pa, and the shear stress was in the range of 7. 82 kPa to 13. 46 kPa in phase of pre-swing, while the other phases were basically the same. Conclusions The mechanical properties of silicon liners affect the pressure distribution of the interface between residual limb and socket, the maximum equivalent stress and shear stress of stump vary greatly during the pre-swing period. We should pay more attention to the process of prosthesis fitting.

參考文獻:

服務(wù)與反饋:
文章下載】【加入收藏
提示:您還未登錄,請登錄!點此登錄
 
友情鏈接  
地址:北京安定門外安貞醫(yī)院內(nèi)北京生物醫(yī)學(xué)工程編輯部
電話:010-64456508  傳真:010-64456661
電子郵箱:[email protected]