51黑料吃瓜在线观看,51黑料官网|51黑料捷克街头搭讪_51黑料入口最新视频

設(shè)為首頁 |  加入收藏
首頁首頁 期刊簡介 消息通知 編委會(huì) 電子期刊 投稿須知 廣告合作 聯(lián)系我們
基于光電容積脈搏波波形分析的運(yùn)動(dòng)負(fù)荷評(píng)價(jià)

Exercise load test based on photoelectric pulse wave assessment

作者: 吳瑋瑩  戰(zhàn)鵬弘  張志敏  王玲  樊瑜波  張弛 
單位:<span style="font-family:宋體">北京航空航天大學(xué)生物與醫(yī)學(xué)工程學(xué)院(北京</span> 100191<span style="font-family:宋體">)</span>
關(guān)鍵詞: 脈搏波;  能量消耗;  運(yùn)動(dòng)負(fù)荷;  線性回歸;  傳感器; 
分類號(hào):R318.04
出版年·卷·期(頁碼):2018·37·2(136-143)
摘要:

Objective Energy consumption is the most direct measurement method for exercise load. The objective of this paper is to use the pulse waveform to measure the exercise load, which may provide foundation for the technology of exercise load test based on wearable devices. Methods The experiment is taken on 32 normal people with the age between 18 and 60 years old, with the finger-type photoelectric pulse wave sensor to measure the pulse wave, and the K4b2 pulmonary function equipment to measure the energy consumption as the golden standard to get the relationship between the pulse wave and energy consumption. Results The period of pulse wave, the amplitude of the main pulse wave and the area of the pulse waveform are more stable in the quiescent state, and decrease in the motion state with increased standard deviations of these three parameters. The experimental results show that the relationship between the integration on time for the pulse waveform amplitude and the energy consumption is linear, and the slope for the optimum fitting line is a constant. Conclusions The exercise load test with finger-type photoelectric pulse wave sensor is available. The pulse waveform feature can fit the energy consumption correctly to measure the exercise load.

參考文獻(xiàn):

[1]Gaesser GA, Brooks GA.Metabolic bases of excessive postexercise oxygen consumption:a review[J].Medicine&Science in Sports&Exercise, 1984, 16 (1) :29-43.

[2]Qi BB, Wu XM, Huang YS.The least squares polynomial fitting design denoise based on the volume pulse wave detection system[J].Chinese Journal of Medical Physics, 2009, 26 (6) :1521-1523.

[3]Jiang YP, Li YW.Pulse wave signal processing based on the lifting scheme[J].Computer Simulation, 2006, 23 (7) :98-100.

[4]Yu E, He D, Su Y, et al.Feasibility analysis for pulse rate variability to replace heart rate variability of the healthy subjects[C]//Shenzhen:Robotics and Biomimetics (ROBIO) , 2013IEEE International Conference on, 2013:1065-1070.

[5]Weir JB.New methods for calculating metabolic rate with special reference to protein metabolism[J].The Journal of Physiology, 1949, 109 (1-2) :1-9.

[6]Tsushima M, Kyotani S, Nakano S, et al.Diagnosis of early stages of atherosis and sclerosis of carotid artery and risk factors.The pulse wave velocity (PWV) , ankle-brachial index (ABI) , and the intima-media complex thickness (IMT) in inhabitants[J].Journal of the Japanese Association for Cerebro-cardiovascular Disease Control, 2002, 37 (2) :117-124.

[7]van de Vosse FN, Stergiopulos N.Pulse wave propagation in the arterial tree[J].Annual Review of Fluid Mechanics, 2011, 43:467-499.

[8]Huybrechts S, Devos D, Vermeersch S, et al.Carotid—femoral pulse wave velocity:age adjusted distance estimation:PP.35.193[J].Journal of Hypertension, 2011, 29 (Suppl) :e485.

[9]Kawakami M, Koda M, Murawaki Y.The prevalence of atherosclerosis in cirrhotic patients:assessment of two aspects of atherosis and sclerosis[J].Hepatology Research, 2007, 37 (2) :152-157.

[10]van den Bosch HCM, Westenberg JJM, Setz-Pels W, et al.Sitespecific association between distal aortic pulse wave velocity and peripheral arterial stenosis severity:a prospective cardiovascular magnetic resonance study[J].Journal of Cardiovascular Magnetic Resonance, 2015, 17 (1) :2.

[11]Taniwaki H, Kawagishi T, Emoto M, et al.Correlation between the intima-media thickness of the carotid artery and aortic pulse-wave velocity in patients with type 2 diabetes.Vessel wall properties in type 2 diabetes[J].Diabetes Care, 1999, 22 (11) :1851-1857.

[12]Liu B, Zhu H, Ren X.De-noising and measurement of pulse wave velocity of the wavelet[J].Journal of Biomedical Engineering, 2011, 28 (1) :54-57.

[13]De MC, van der Hoeven GM, van Vollenhoven E, et al.Determination of central and peripheral pulse wave velocity of children between 2 and 12 years[J].Pflügers Archiv European Journal of Physiology, 1970, 314 (2) :174.

[14]van der Meer RW, Diamant M, Westenberg JJM, et al.Magnetic resonance assessment of aortic pulse wave velocity, aortic distensibility, and cardiac function in uncomplicated type 2diabetes mellitus[J].Journal of Cardiovascular Magnetic Resonance, 2007, 9 (4) :645-651.

[15]American College of Sports Medicine, Kaminsky LA.ACSM’s health-related physical fitness assessment manual[M].Amsterdam:Wolters Kluwer Health/Lippincott Williams&Wilkins, 2014.

服務(wù)與反饋:
文章下載】【加入收藏
提示:您還未登錄,請登錄!點(diǎn)此登錄
 
友情鏈接  
地址:北京安定門外安貞醫(yī)院內(nèi)北京生物醫(yī)學(xué)工程編輯部
電話:010-64456508  傳真:010-64456661
電子郵箱:[email protected]