射頻消融腎交感神經(jīng)的體外實驗研究

Ex-vivo experimental study in hepatic vascular to simulate the radiofrequency ablation of renal sympathetic nerve

作者: 董彤  程妍妍  田甄  劉憶南  南群 
單位:<span style="font-family:宋體">北京工業(yè)大學生命科學與生物工程學院(北京</span>100124<span style="font-family:宋體">)</span>
關(guān)鍵詞: 射頻消融;腎交感神經(jīng);體外牛肝血管;溫度場;頑固性高血壓 
分類號:R318.01
出版年·卷·期(頁碼):2018·37·3(265-272)
摘要:

Objective Radiofrequency ablation of renal sympathetic nerve in the treatment of resistant hypertension has obtained certainly effect in clinical. It is inserted into the renal artery to release energy by radiofrequency catheter, selectively destroyed renal sympathetic nerve fibers on the outer membrane, finally to achieve the antihypertensive by reducing the excitability. But the radio-frequency energy penetrating power of sympathetic nerve influenced by ablation conditions. This experiment adopts the ex-vivo hepatic vascular to simulate renal artery to explore the change of temperature field under the different ablation conditions. Methods We used the blood vessels of ex-vivo bovine liver (n = 21) , with blood flow simulated by water pump. For collecting the temperature field data for perivascular tissues and the flow downstream, measured from 8-10 mm above the ablation point and the temperature of the downstream water district to study the impact under the ablation conditions. By changing the ablation time andflow velocity, the ablation results were analyzed under different conditions. Results (1) Ablation point was fixed in water inlet, when the distance form ablation point and temperature measuring point in the center of downstream water increased, the temperature ΔT mean value of water reduced. The water temperature rose by only 1. 11 with 7 cm distance. (2) Ablation time increases by 8 min to 10 min, the water temperature ΔT value and the temperature above the ablation point ΔT value increased. (3) Flow velocity increased from 0. 28 m/s to 0. 365 m/s, the ΔT of water temperature and temperature above the ablation point ΔT value were decreased. (4) For the temperature changes caused by radiofrequency ablation, increased by an average of3. 97 above the ablation point, while 2. 17 in flow center. Conclusions Radiofrequency ablation in blood vessels within 10 min, the temperature of peripheral tissue and downstream flow rise, no more than 6 in maximum. The influence on blood flow is limited, basic verified the feasibility of endovascular radiofrequency ablation therapy.

參考文獻:

服務與反饋:
文章下載】【加入收藏
提示:您還未登錄,請登錄!點此登錄
 
友情鏈接  
地址:北京安定門外安貞醫(yī)院內(nèi)北京生物醫(yī)學工程編輯部
電話:010-64456508  傳真:010-64456661
電子郵箱:[email protected]