51黑料吃瓜在线观看,51黑料官网|51黑料捷克街头搭讪_51黑料入口最新视频

設(shè)為首頁 |  加入收藏
首頁首頁 期刊簡介 消息通知 編委會 電子期刊 投稿須知 廣告合作 聯(lián)系我們
基于微機(jī)電系統(tǒng)加速度傳感器的上肢運動功能評價系統(tǒng)

Evaluation system of upper limb movement function based on microelectro mechical system accelerometer sensor

作者: 汪鵬  王殊軼  徐明哲 
單位:<span style="font-size:14px;font-family:宋體">上海理工大學(xué)醫(yī)療器械與食品學(xué)院(上海</span><span style="font-size:14px;font-family:&#39;Times New Roman&#39;,serif"> 200093</span><span style="font-size:14px;font-family:宋體">)</span>
關(guān)鍵詞: 加速度傳感器;  運動功能評定;  平滑度;  加速度均方根 
分類號:R318.04
出版年·卷·期(頁碼):2018·37·3(285-290)
摘要:

Objective An evaluation system of upper limb movement function based on microelectro mechical system (MEMS) accelerometer sensor is designed to accurately and objectively evaluate the dysfunction of upper limb movement in stroke patients through the index of smoothness and root mean square of acceleration. Methods The system mainly included ATmega128 single-chip microcomputer communication module, this module could transmit data between the upper and lower computer and save the data. The system also included data acquisition module, this module could collect the patient's upper limb motion acceleration in real time by using ADXL345 acceleration sensor. The system was low cost, easy to carry and efficient in tests.Finally, six stroke patients with upper limb hemiplegia rehabilitation (patient group) and four normal healthy adults (healthy group) were recruited. Healthy group performed directional motion with zero load and reduplicate tests of directional motion with gradient load.The data was contrasted between this two groups when patient group and the healthy group were tested of directional motion with zero load. Results Repeat tests of oriented motion with zero load: there were no significant differences among the smoothness (P> 0. 05) and the mean square root of acceleration (P> 0. 05) between numbers in the healthy group. Contrast test of oriented motion with zero load: there were significant differences among the smoothness (P < 0. 05) and no significant differences among the mean square root of acceleration (P> 0. 05) between two groups. Repeat tests of directional motion with gradient load: smoothness increased as the load increased. And the smoothness (P< 0. 001) was significantly linear related to the load by the unitary linear regression analysis. Conclusions The evaluation system of upper limb movement function based on MEMS acceleration sensor can quantitatively evaluate the movement capacity of upper limb in stroke patients through the index of smoothness. Furthermore, the linear relationship between smoothness and load is obtained and provided a new way to evaluate the recovery of stroke patients with upper limb hemiplegia.

參考文獻(xiàn):

服務(wù)與反饋:
文章下載】【加入收藏
提示:您還未登錄,請登錄!點此登錄
 
友情鏈接  
地址:北京安定門外安貞醫(yī)院內(nèi)北京生物醫(yī)學(xué)工程編輯部
電話:010-64456508  傳真:010-64456661
電子郵箱:[email protected]