51黑料吃瓜在线观看,51黑料官网|51黑料捷克街头搭讪_51黑料入口最新视频

設(shè)為首頁 |  加入收藏
首頁首頁 期刊簡介 消息通知 編委會(huì) 電子期刊 投稿須知 廣告合作 聯(lián)系我們
表面肌電檢測(cè)系統(tǒng)上位機(jī)應(yīng)用程序設(shè)計(jì)

A Program Designing of Surface Electromyography-Detected System in PC

作者: 唐志剛  何愛軍  譚慧玲 
單位:南京大學(xué)電子系生物醫(yī)學(xué)電子工程研究所(南京210093)
關(guān)鍵詞: Visual  C++;SEMG;表面肌電檢測(cè)系統(tǒng);MySQL 
分類號(hào):
出版年·卷·期(頁碼):2010·29·5(479-482)
摘要:

表面肌電是反映人體肌肉狀態(tài)的電信號(hào),是現(xiàn)代醫(yī)療中非常有效的診療工具。它對(duì)醫(yī)學(xué)研究、工效學(xué)、運(yùn)動(dòng)學(xué)等領(lǐng)域的發(fā)展有很大影響。本文在Visual C++6.0環(huán)境下,設(shè)計(jì)開發(fā)表面肌電(SEMG)檢測(cè)系統(tǒng)上位機(jī)應(yīng)用程序。程序功能包括利用算法提取表面肌電重要參數(shù)、計(jì)算SEMG信號(hào)功率譜、實(shí)時(shí)顯示SEMG波形、打印計(jì)算參數(shù)與波形,以及使用MySQL數(shù)據(jù)庫管理記錄的SEMG數(shù)據(jù)。程序開發(fā)后期,使用三片電極測(cè)試了測(cè)試者右手尺側(cè)碗屈肌、橈側(cè)碗屈肌和肱橈肌三個(gè)部位,成功獲得測(cè)試者肌肉靜態(tài)與動(dòng)態(tài)時(shí)的肌電波形和參數(shù)。
 

Surface electromyography is a kind of human electric signals. It can reflect the condition of muscles and is viewed as a very powerful tool of diagnosis and treatment in modern medical techniques. The application of which plays a great role in the development of medical research, ergonomics, sports science and so on. In this paper,a program of surface electromyography-detected system was designed and developed under Visual C++6.0 in personal computer. This program could extract some important parameters from SEMG signal,calculate SEMG power spectrum by the use of algorithms,diplay SEMG waveform in real-time,print calculated SEMG parameters and waveform,and manage all the recorded data of SEMG by using MySQL. At the last stage of developing program,three electrodes were used to test flexor carpum radialis, flexor carpum ulnaris and brachioradialis on the right hand of subject,whose SEMG waveform and parameters in the static and active condition were successfully recorded.

參考文獻(xiàn):

[1]Konrad P. The ABC of EMG: A practical introduction to kinesiological electromyography[S]. Version 1.0. Noraxon, Inc, USA:2005.
[2]Zhou P, Rymer WZ. Can standard surface EMG processing parameters be used to estimate motor unit global firing rate?[J]J Neur Eng, 2004, 1: 99-110.
[3]Clancy EA, Bouchard S, Rancourt D. Estimation and application of EMG amplitude during dynamic contractions[J]. IEEE Eng Med Biol Mag, 2001, 20(6):47-54.
[4]李俊, 于良耀, 班學(xué)鋼, 等. Visual C++6.0 實(shí)用教程[M]. 北京:人民郵電出版社,2000: 189-302.
[5]加玉濤,羅志增. 肌電信號(hào)特征提取方法綜述[J]. 電子器件,2007, 30(1):722-726.
[6]程佩青.數(shù)字信號(hào)處理教程[M]. 北京:清華大學(xué)出版, 2003:87-200.
[7]Leon Atkinson. MySQL核心編 : 高級(jí)開者指南[M].  周靖,許青松譯.北京:清華大學(xué)出版社, 2003:1-538.