51黑料吃瓜在线观看,51黑料官网|51黑料捷克街头搭讪_51黑料入口最新视频

設為首頁 |  加入收藏
首頁首頁 期刊簡介 消息通知 編委會 電子期刊 投稿須知 廣告合作 聯(lián)系我們
醫(yī)學超聲造影劑研究進展

Research Advances of Medical Ultrasound Contrast Agent

作者: 袁在賢  王愛琴  丁明躍  張旭明  尉遲明 
單位:華中科技大學生命科學與技術學院,圖像信息處理與智能控制教育部重點實驗室(武漢430074)
關鍵詞: 超聲造影劑;超聲診斷;超聲治療;安全性;納米泡 
分類號:
出版年·卷·期(頁碼):2010·29·6(650-654)
摘要:

本文首先對超聲造影劑(UCA)的定義、發(fā)展、結構特點以及臨床應用現(xiàn)狀等進行概述,重點介紹了UCA在超聲診斷和超聲治療方面的應用現(xiàn)狀,然后探討了UCA安全性問題,最后介紹了納米級UCA等最新研究進展。本文對全面了解UCA特性、應用及安全性問題具有重要參考價值。

A summary about the definition,development,structure characteristics and clinical application of ultrasound contrast agent (UCA) is presented firstly in this paper.Then,we  concentrate to introduce the application status of UCA in ultrasound diagnosis and ultrasound treatment.The discussion about safety problem of UCA is following.Lastly the latest research progresses of nanobubble UCA are described.This paper will be very important to thoroughly understand the characteristic,application status and secure problems of UCA.

參考文獻:

[1]Gramiak R,Shah P.Echocardiography of the aortic root [J].Investigative Radiology,1968,3:356-366.
[2]Hughes MS,Lanza GM,Marsh JN,et al.Targeted ultrasonic contrast agents for molecular imaging and therapy:a brief review[J].MEDICA,2003,47:66-73.
[3]Schneider M.Molecular imaging and ultrasound-assisted drug delivery[J].Journal of Endourology,2008,22(4):795-802.
[4]Armstrong WF,Ryan T.Stress echocardiography from 1979 to present [J].Journal of the American Society of Echocardiography,2008,21:22–28.
[5]Kaneko Y,Maruyama T,Takegami K,et al.Use of a microbubble agent to  increase the effects of high intensity focused ultrasound on liver tissue[J].European Radiology,2005,15:1415–1420.
[6]Quaia E,Palumbo A,Rossi S,et al.Characterization of liver tumors insonated at low transmit power after microbubble contrast agent injection:comparison of visual and quantitative analysis in diagnostic performance[J].AJR Am J Roentgenol,2006,186:1560–1570.
[7]Piscaglia F,Corradi F,Mancini M,et al.Real time contrast enhanced ultrasonography (CEUS) in detection of liver metastases from gastrointestinal cancer[J].BMC Cancer,2007,7:171–184.
[8]Quaia ED,Onofrio M,Palumbo A,et al.Comparison of contrast-enhanced Ultrasonography versus baseline ultrasound and contrast-enhanced computed tomography in metastatic disease of the liver:diagnostic performance and confidence[J].European Radiology,2006,16:1599–1609.
[9]Wilson SR,Burns PN.An algorithm for the diagnosis of focal liver masses using microbubble contrast-enhanced pulse inversion sonography [J].AJR Am J Roentgenol,2006,86:1401–1412.
[10]David Cosgrove,Chris Harvey.Clinical uses of microbubbles in diagnosis and treatment [J].Med Biol Eng Comput,2009,47:813–826.
[11]Behm C,Lindner J.Cellular and molecular imaging with targeted contrast ultrasound[J].Ultrasound Quarterly,2006,22(1):67–72.
[12]華興,高云華.超聲波與聲學造影劑在溶栓中的作用[J].臨床超聲醫(yī)學雜志,2006,(7):425-427.
[13]Alonso A,Della Martina A,Stroick M,et al.Molecular imaging of human thrombus with novel abciximab immunobubbles and ultrasound[J] .Stroke,2007,38:1508–1514.
[14]陳松.納米液態(tài)氟碳微球超聲造影劑的制備及體外尋靶實驗研究[D].重慶:重慶醫(yī)科大學,2008.
[15]Yanagisawa K,Moriyasu F,Miyahara T,et al.Phagocytosis of ultrasound contrast agent microbubbles by Kupffer cells[J].Ultrasound Med Biol,2007,33:318–325.
[16]Gail ter Haar.Safety and bio-effects of ultrasound contrast agent[J].Medical and Biological Engineering and Computing,2009,47:893–900.
[17]Miller DL,Averkiou MA,Brayman AA,et al.Bioeffects considerations for diagnostic ultrasound contrast agents[J].J Ultrasound Med,2008,27:611–632.
[18]Barnett SB,Duck F,Ziskin M.WFUMB symposium on safety of ultrasound in medicine:conclusions and recommendations on biological effects and safety of ultrasound contrast agents,2006[J].Ultrasound Med Biol,2007,33:233–234.
[19]Main ML,Goldman JH,Grayburn PA.Thinking outside the “box”-the ultrasound contrast controversy[J].Journal of the American College of Cardiology,2007,50:2434–2437.
[20]Kusnetzky L,Khalid A,Khumri T,et al.Acute mortality in hospitalized patients undergoing echocardiography with and without an ultrasound contrast agent:results in 18,671 consecutive studies[J].Journal of the American College of Cardiology,2008,51:1704–1706.
[21]Duck F.Hazards,risks and safety of diagnostic ultrasound[J].Med Eng Phys,2008,30:1338–1348.
[22]Dijkmans P,Visser C,Kamp O.Adverse reactions to ultrasound contrast agents:is the risk worth the benefit? [J].European Journal of Echocardiography,2005,6(5):363–366.
[23]Claudon M,Cosgrove D,Albrecht T,et al.Guidelines and good clinical practice recommendations for contrast enhanced ultrasound (CEUS)—update 2008[J].Ultraschall Med,2008,29:28–44.

服務與反饋:
文章下載】【加入收藏
提示:您還未登錄,請登錄!點此登錄
 
友情鏈接  
地址:北京安定門外安貞醫(yī)院內(nèi)北京生物醫(yī)學工程編輯部
電話:010-64456508  傳真:010-64456661
電子郵箱:[email protected]