基于超聲衰減系數(shù)的微波熱療無損測(cè)溫

Noninvasive temperature estimation of microwave hyperthermia based on ultrasound attenuation coefficients

作者: 盛磊  吳薇薇  周著黃  吳水才  高宏建  曾毅 
單位:                      北京工業(yè)大學(xué)生命科學(xué)與生物工程學(xué)院(北京100124)        
關(guān)鍵詞:                     微波;熱療;測(cè)溫;超聲;衰減          
分類號(hào):
出版年·卷·期(頁碼):2014·33·6(620-626)
摘要:

           目的 熱療的引導(dǎo)、療效及劑量控制都需要溫度監(jiān)測(cè),本文旨在探索一種基于超聲衰減系數(shù)的微波熱療無損測(cè)溫新方法。方法 利用水浴加熱實(shí)驗(yàn)系統(tǒng),以新鮮體外豬肝組織為研究對(duì)象,通過采集不同溫度下的超聲原始回波信號(hào),分析不同溫度下組織的超聲衰減系數(shù),建立超聲衰減系數(shù)與溫度相關(guān)性模型,用于微波加熱實(shí)驗(yàn)過程中溫度的檢測(cè)。結(jié)果 超聲衰減系數(shù)與溫度相關(guān)性模型為:超聲衰減系數(shù)=0.513×溫度-0.80。超聲衰減系數(shù)在微波熱療低溫段(≤50℃)測(cè)溫誤差較小(<5℃),在高溫段(>50℃)測(cè)溫誤差較大(>10℃)。結(jié)論 超聲衰減系數(shù)可用于常規(guī)熱療無損測(cè)溫。微波熱療溫度分布不均使得檢測(cè)較為困難。利用正常與熱凝固組織超聲衰減系數(shù)的差異進(jìn)行熱凝固區(qū)的檢測(cè)具有一定優(yōu)勢(shì)。    

       Objective Temperature monitoring is essential for hyperthermia guidance, treatment efficacy and thermal dose control. The objective of this study is to explore a new method for noninvasive temperature estimation of microwave hyperthermia based on ultrasound attenuation coefficients (UAC). Methods In this study, water bath heating experiments were performed to fresh in vitro porcine liver tissues, and the original ultrasonic echo signals at different temperatures were collected. The UAC of porcine liver tissues at different temperatures were analyzed, and the correlation between UAC and temperature was derived for temperature estimation in microwave heating experiments. Results The correlation between UAC and temperature was: UAC = 0.513×Temperature-0.80. Temperature estimation based on UAC for microwave hyperthermia had a smaller error (<5℃) in="" the="" temperature="" range="" of="" and="" a="" bigger="" error="">10℃) in the temperature range of >50℃. Conclusions The UAC might be used for noninvasive temperature estimation of mild hyperthermia. It was difficult to accurately estimate the temperature because of the heterogeneity of temperature distribution in microwave hyperthermia. It might be a potential approach for detecting thermal coagulation zones based on the difference between the UAC of normal and coagulated tissues.

參考文獻(xiàn):

服務(wù)與反饋:
文章下載】【加入收藏
提示:您還未登錄,請(qǐng)登錄!點(diǎn)此登錄
 
友情鏈接  
地址:北京安定門外安貞醫(yī)院內(nèi)北京生物醫(yī)學(xué)工程編輯部
電話:010-64456508  傳真:010-64456661
電子郵箱:[email protected]